Multiparameterprobes

Probes with diameter 70 mm

 

8 input channels

• Models with built-in data logger and rechargeable battery
• OEM models for external data loggers
• Submersible to 350 m
• Extractable sensors
• Internal or external power supply 

SA 8060.101

Model with 6 sensors: Depth, Temperature, E.Conductivity, pH, ORP, D. Oxygen.
Max depth 20 m, data logger and internal battery. 

Specifications 

Date                                                    DD-MM-YY (only SA8060.10x)
Hour                                                   hh-mm-ss (only SA8060.10x)
Level                                                  0/20.000 m. - 0/350.00 m. max.
Temperature                                     -5.00/+55.00 °C
Conductivity                                      0/6.000 mS autorange
                                                       0/60.000 mS
Temperature Coefficient                 0/3.50 %/°C
Reference Temperature                 10/30 °C
pH                                                       0/14.000 pH
Redox                                                ± 1100.0 mV
Dissolved Oxygen                           0/200.00 mmHg
                                                  0/200.00 %air
                                                 0/20.000 PPM
                                                   0/20.000 mg/l 

Secondary parameters:

Pressure                                            500/800 mmHg
Salinity                                               0/60.000 PPM
Relative Humidity                            0/100 %
Identification of probe                     0 / 32
Programmable acquisition                         Time interval
(Stand alone)                                    Level interval
Power supply                                    2.7/4.8 Vdc
                                                       external 12 Vdc 30 mA max
Internal batteries                              Ni/Cd rechargeable 1800 mAh
Interface serial                                  RS485 or RS232 D
Operating Pressure                                     30 bar max.
Material                                              PVC/AISI 316
Length                                               510 mm
Diameter                                            70 mm max.
Weight                                               2 Kg max.
Connector                                         IP 68 - 100 bar oceanographic
Option                                                MODBUS protocol 

 