The Instrument is equipped with two SPDT control relays. Each control relay may be programmed for set-point, high/low, hysteresis or delay time actuation.The unit recognizes automatically standard solutions. The operator may calibrate at any Turbidity value. Analog output Either a 0/20 mA or 4/20 mA programmable and isolated output may be selected, for use as an interface with computers or data loggers. The input range corresponding to the output is programmable. The unit contains a SPST relay designated as an alarm relay. This relay may be used to warn of conditions that may indicate operational problems. The relay will activate on either high/low value conditions, or on failure of the control relays to maintain proper control. In addition, this relay may be activated for dirty probe, lack of water in the cell and external light too high.
The Instrument is equipped with two SPDT control relays. Each control relay may be programmed for set-point, high/low, hysteresis or delay time actuation.The unit recognizes automatically standard solutions. The operator may calibrate at any Turbidity value. Analog output Either a 0/20 mA or 4/20 mA programmable and isolated output may be selected, for use as an interface with computers or data loggers. The input range corresponding to the output is programmable. The unit contains a SPST relay designated as an alarm relay. This relay may be used to warn of conditions that may indicate operational problems. The relay will activate on either high/low value conditions, or on failure of the control relays to maintain proper control. In addition, this relay may be activated for dirty probe, lack of water in the cell and external light too high.
Main Features: | |
- Manual, automatic operation | |
- Selectable scales with auto range | |
- Dual filter software | |
- 0/20 or 4/20 mA selectable output, programmable on the inputscale. | |
- 2 Set point with min/max function, hysteresis and adjustabledelay | |
- Signal for empty cell, or dirty cell | |
- Alarm: min/max turbidity, set point timing, dirty lens, empty cell, | |
- external light too high Check signal of dirty lens | |
- Autoclean relay with programmable cycle repetition, cleaning andholding time | |
Our more than 75 years long noteworthy existence in the market in itself is a proof of satisfaction ...
Home
About
Complete Catalogue
Services & Support
New Launch
Career
Events & Exhibition
Contact Us
Laboratory & Industrial Electrodes / Sensors
Analytical Instruments
Buffer Solutions
Dosing and Metering Products
Online Water Quality Analysers Instruments
SCR Power Controllers
Temperature Controllers / Profilers
P.O. Gagwana - 305023, Distt. Ajmer (Raj.) India |
|
info@toshcon.com support@toshcon.com |
|
+91 9829112345 +91-145-2971131/2/3 |