MC7687


The instrument can be configured for the regulation of conductivity or TDS or other indirect measurements during installation; from the configuration menu it is also possible to activate the display of resistivity values.It is designed for manual and automatic temperature compensation using RTD Pt 100 or RTD Pt1000. The device can perform the following functions: - view the measurement; - automatically adjust the measurement values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - activate the alarm for measurement values outside the limits, excessive permanence of the set points and closure of the logic inputs; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.

The instrument can be configured for the regulation of conductivity or TDS or other indirect measurements during installation; from the configuration menu it is also possible to activate the display of resistivity values.It is designed for manual and automatic temperature compensation using RTD Pt 100 or RTD Pt1000. The device can perform the following functions: - view the measurement; - automatically adjust the measurement values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - activate the alarm for measurement values outside the limits, excessive permanence of the set points and closure of the logic inputs; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.

Main features
- Multi-line graph
- Inputs: Electronics digital probes and transmitters.
- 2 logical inputs for hold / alarm function
- 2 set points Relay with PID Action
- Alarm: min/max values selectable on the entire chosen scale
- 2 analog outputs: 0-20 mA / 4-20 mA for PID or measurement (main or temperature)
- Self-cleaning function
- Configuration of parameters on two levels using access codes chosen by the operator

Related Products

Our more than 75 years long noteworthy existence in the market in itself is a proof of satisfaction ...

Contact Us

P.O. Gagwana - 305023,
Distt. Ajmer (Raj.)
India
info@toshcon.com
support@toshcon.com
+91 9829112345
+91-145-2971131/2/3
© 2024 Toshcon. All rights reserved.
Privacy Policy | Terms & conditions
Menu Color: