Glass Body These Glass-body, Conductivity electrode/cell is designed to conductivity testing application for laboratory and field use. Suitable for tap water and quality control check in water purification plant. Each type of conductivity cell has two models with k=0.1 cm-1 and k=1.0 cm-1 cell constants. When selecting a conductivity cell, check the expected conductivity of the sample and then look at the cell constants of conductivity cells. Choose a conductivity cell that covers the expected sample conductivity. The higher the conductivity value of sample, the higher the cell constant required. A conductivity cell with k=1.0 cm-1 cell constant is the most commonly used because it measures low to high conductivity.
Glass Body These Glass-body, Conductivity electrode/cell is designed to conductivity testing application for laboratory and field use. Suitable for tap water and quality control check in water purification plant. Each type of conductivity cell has two models with k=0.1 cm-1 and k=1.0 cm-1 cell constants. When selecting a conductivity cell, check the expected conductivity of the sample and then look at the cell constants of conductivity cells. Choose a conductivity cell that covers the expected sample conductivity. The higher the conductivity value of sample, the higher the cell constant required. A conductivity cell with k=1.0 cm-1 cell constant is the most commonly used because it measures low to high conductivity.
BENEFITS | |
- Conductivity Cell covers wide range uS to mS. | |
- Stable & quick response. | |
- Intended for laboratory use. | |
- Glass-body conductivity cells are chemical-resistant. They can be used in aqueous samples as well as in samples containing organic solvents. | |
- Typically, a low conductivity solution is measured with a low cell having a k=0.1 cm-1 cell constant to prevent absorption of carbon dioxide (CO2) from air, which can affect the conductivity value. | |
- A high conductivity solution is measured with a high cell having a k=1.0 cm-1 cell constant | |
- Long life, easy cleaning to avoid contamination of the electrode to ensure correct results. | |
- The same electrodes can also be used for measuring Resistivity/ TDS/ Salinity. | |
- Available with BNC, 5 pin connectors & Banana Pin. | |
- Suitable/ compatible with mostly all make Meters/ Analysers. | |
Our more than 75 years long noteworthy existence in the market in itself is a proof of satisfaction ...
Home
About
Complete Catalogue
Services & Support
New Launch
Career
Events & Exhibition
Contact Us
Laboratory & Industrial Electrodes / Sensors
Analytical Instruments
Buffer Solutions
Dosing and Metering Products
Online Water Quality Analysers Instruments
SCR Power Controllers
Temperature Controllers / Profilers
P.O. Gagwana - 305023, Distt. Ajmer (Raj.) India |
|
info@toshcon.com support@toshcon.com |
|
+91 9829112345 +91-145-2971131/2/3 |