CL6587.103


The possibility of using sensors for the main oxidizing substances, such as free, combined, and total residual chlorine, dissolved ozone and chlorine dioxide, residual hydrogen peroxide and peracetic acid, makes it suitable for many applications and types of systems. The device can perform the following functions: - view the measurements of oxidants, pH, redox and temperature; - automatically adjust the oxidant, pH and redox values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - provide an RS485 and Modbus digital output (function 03); - activate the alarm for measurement values outside the limits, excessive permanence of the set points and closure of the logic inputs; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.

The possibility of using sensors for the main oxidizing substances, such as free, combined, and total residual chlorine, dissolved ozone and chlorine dioxide, residual hydrogen peroxide and peracetic acid, makes it suitable for many applications and types of systems. The device can perform the following functions: - view the measurements of oxidants, pH, redox and temperature; - automatically adjust the oxidant, pH and redox values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - provide an RS485 and Modbus digital output (function 03); - activate the alarm for measurement values outside the limits, excessive permanence of the set points and closure of the logic inputs; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.

Main features
- Display: multi-line graph
- Entrances:
- potentiostatic or polarographic sensors (2 or 3 wires)
- glass or antimony pH electrode
- redox electrode
- Pt100 or Pt1000
- 2 logical inputs for hold / alarm function
- Selectable scales in ppm - mg/l
- Stairs:
- 200.0 ppb - µg/l
- 2.000 / 20.00 / 200.0 / 2000 ppm - mg/l
- 0 ÷ 14.00 pH
- -2000 ÷ 2000 mV
- Temperature range: -10.0 / 110.0 °C - 14.0 / 230.0 °F
- Manual and automatic temperature compensation.
- 2 set points for each input addressable on each of the 4 relays
- Alarm: min/max values selectable on the entire scale.
- 2 analog outputs: 0-20 mA / 4-20 mA for PID or measurement (main or temperature)
- RS485 and Modbus digital output (function 03)
- Self-cleaning function
- Configuration of parameters on two levels using access codes chosen by the operator
- Ambient temperature: 0/50 °C
- Power supply: 85/264 V - 50/60 Hz
- Container: ABS protection IP 66
- Dimensions: 256 x 230 x 89 mm
- Registered ornamental model: 002564666-002

Related Products

Our more than 75 years long noteworthy existence in the market in itself is a proof of satisfaction ...

Contact Us

P.O. Gagwana - 305023,
Distt. Ajmer (Raj.)
India
info@toshcon.com
support@toshcon.com
+91 9829112345
+91-145-2971131/2/3
© 2024 Toshcon. All rights reserved.
Privacy Policy | Terms & conditions
Menu Color: