The instrument uses potentiostatic or polarographic membrane sensors.It is designed for manual and automatic temperature compensation using RTD Pt100 or Pt1000 integrated in the cell or separately external. The instrument also provides temperature measurement. The device can perform the following functions: - view the measurement; - automatically adjust the measurement values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - activate the alarm if the measurement values are outside the limits; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.
The instrument uses potentiostatic or polarographic membrane sensors.It is designed for manual and automatic temperature compensation using RTD Pt100 or Pt1000 integrated in the cell or separately external. The instrument also provides temperature measurement. The device can perform the following functions: - view the measurement; - automatically adjust the measurement values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - activate the alarm if the measurement values are outside the limits; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.
Main features | |
• Display: multi-line graph | |
• Inputs: potentiostatic or polarographic sensors (2 or 3 wires) | |
• 2 logical inputs for hold / alarm function | |
• Selectable scales in ppm - mg/l | |
• Scales: 200.0 ppb - µg/l / 2.000 / 20.00 / 200.0 / 2000 ppm - mg/l | |
• Temperature range: -10.0 / 110.0 °C - 14.0 / 230.0 °F | |
• Manual and automatic temperature compensation | |
• Reference temperature 20 °C | |
• 2 set points Relay with PID Action | |
• Alarm: min/max values selectable on the entire scale, | |
• 2 analog outputs: 0-20 mA / 4-20 mA for PID or measurement (main or temperature); | |
• Self-cleaning function | |
• Configuration of parameters on two levels using access codes chosen by the operator | |
• Ambient temperature: 0/50 °C | |
Our more than 75 years long noteworthy existence in the market in itself is a proof of satisfaction ...
Home
About
Complete Catalogue
Services & Support
New Launch
Career
Events & Exhibition
Contact Us
Laboratory & Industrial Electrodes / Sensors
Analytical Instruments
Buffer Solutions
Dosing and Metering Products
Online Water Quality Analysers Instruments
SCR Power Controllers
Temperature Controllers / Profilers
P.O. Gagwana - 305023, Distt. Ajmer (Raj.) India |
|
info@toshcon.com support@toshcon.com |
|
+91 9829112345 +91-145-2971131/2/3 |