Chlorine Analyser CL6587


The instrument uses potentiostatic or polarographic membrane sensors.It is designed for manual and automatic temperature compensation using RTD Pt100 or Pt1000 integrated in the cell or separately external. The instrument also provides temperature measurement. The device can perform the following functions: - view the measurement; - automatically adjust the measurement values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - activate the alarm if the measurement values are outside the limits; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.

The instrument uses potentiostatic or polarographic membrane sensors.It is designed for manual and automatic temperature compensation using RTD Pt100 or Pt1000 integrated in the cell or separately external. The instrument also provides temperature measurement. The device can perform the following functions: - view the measurement; - automatically adjust the measurement values; - provide, as an alternative to PID regulation, 0-20 mA or 4-20 mA measurement outputs programmable on the main measurement and temperature scale; - activate the alarm if the measurement values are outside the limits; - activate the alarm or keep the instrument in hold conditions using two external contacts; - activate automatic or manual sensor cleaning cycles.

Main features
• Display: multi-line graph
• Inputs: potentiostatic or polarographic sensors (2 or 3 wires)
• 2 logical inputs for hold / alarm function
• Selectable scales in ppm - mg/l
• Scales: 200.0 ppb - µg/l / 2.000 / 20.00 / 200.0 / 2000 ppm - mg/l
• Temperature range: -10.0 / 110.0 °C - 14.0 / 230.0 °F
• Manual and automatic temperature compensation
• Reference temperature 20 °C
• 2 set points Relay with PID Action
• Alarm: min/max values selectable on the entire scale,
• 2 analog outputs: 0-20 mA / 4-20 mA for PID or measurement (main or temperature);
• Self-cleaning function
• Configuration of parameters on two levels using access codes chosen by the operator
• Ambient temperature: 0/50 °C

Related Products

Our more than 75 years long noteworthy existence in the market in itself is a proof of satisfaction ...

Contact Us

P.O. Gagwana - 305023,
Distt. Ajmer (Raj.)
India
info@toshcon.com
support@toshcon.com
+91 9829112345
+91-145-2971131/2/3
© 2024 Toshcon. All rights reserved.
Privacy Policy | Terms & conditions
Menu Color: