7615 SERIES

96x96 DIN 43700

 

• High quality

• 3 1/2 digit LED display

• Automatic temperature compensation

• 0/20mA 4/20mA adjustable output

• 2 min/max control relays

• Extractable terminal blocks

• Isolated output as option

 

General informations 

This series of controllers has been designed to carry out the measurement

and the regulation of: 

• pH

• O.R.P

• E. Conductivity

• Free Chlorine

• Temperature

 

in industrial processes, with continuous readings on digital indicators.

 

These instruments give both a valid, low cost measurement and regulation

system for small industrial and ecological plants, and they can be used as

0/20 mA or 4/20 mA visualized transmitters for field applications.

 

Connections are made by means of two extractable terminal blocks on the

rear side of the instrument, which allow easy cables connection and easy

maintenance of the instrument.

 

The panel mounting instrument's enclosure is designed according to the

DIN 43700 standards and it consists of a plastic case with metallic front

panel coated with a polycarbonate membrane, to ensure the maximum

anticorrosion characteristics.

 

A transparent splashproof front door can be added to the housing, in order

to protect the unit from excessive moisture or corrosive fumes.

 

The package is supplied complete with fixing clamps for panel mounting. 

Functional specifications 

Display

The controller provides a digital readout on a 3 1/2 digit display that

allows reading even at long distances. 

Calibration

The zero and the sensitivity adjustment is done by means of trimmers

mounted on the front panel.

Control relays

The controller features two on-off regulators. 

Set-points are independent and their value is displayed by pushing a button

on the front panel. 

Relays activation is displayed on the front panel by their corresponding

LEDs. 

Analog output 

Instruments provide a 0/20 mA analog output (4/20 mA, volt on request).

The 0/20 mA output may be adjusted to 4/20 mA by the operator. 

Options

Functional features may be extended by following options:

091.203: 0/5 s delay and selectable min/max relays function

091.311: 4/20 mA output

091.362: isolated analog output

091.403: 24 Vac power supply 

Common Specifications 

Zero                            : adjustment: ±15%

Slope adjustment     : ±20%

Output                        : 0/20 mA dc 300 ohm max.

Regulator hysteresis: ±0,25%

Switching Time        : < 0.5 s

Relay contacts          : SPDT 5 A 220 V resistive load

Temperature             : 0/50 °C

Humidity                    : 95% without condensate

Voltage                      : 110/220 V ±10% 50/60 Hz

Power                         : 3 VA max.

Terminal blocks        : extractable

Weight                       : 500 g

Size: 96 x 96 x 150 mm (1/4 DIN)

 

PH 7615

 

pH controller

 

Input signal comes directly from pH electrode.

 

The controller provides an Automatic Temperature Compensation with the Pt100 device.

 

Specifications

 

Input: pH electrode (glass/Ref)

 

ATC: RTD Pt100

 

Scale: 0/14.00 pH

 

Input Current: < 2 pA

 

Input Impedance: > 1012 ohm

 