IC 7685.010

Ion concentration controller with auto calibration

and auto cleaning functions.

 

 

• Applications:

- with ISE electrodes

- water softeners

- drinking water

- electroplating industry

- Aluminum surface coating

- CO2 in biotechnology

 

• Input from any ISE and CO2 electrodes

• Input form Pt100 3 wires

 

• Measuring unit: PPM - mg/l - gr/l - mbar - mmHg

• Measuring range from 0.01 to 1000

• Autoranging

• Up to 5 points calibration

 

• Temperature readout

• Calibration parameters display

• Dual set-point and alarm conditions display

• Automatic or manual temperature compensation

• Dual filter software

 

• Isolated output:

- 0/20 mA or 4/20 mA selectable

- programmable input on the span

- dual output as option

 

• Automatic or manual operation

• Dual set-point with hysteresis, delay, and min/max

programmable functions

 

• Alarm:

- continuous/flashing

- min/max and delay programmable

- on set-points timing

 

• Auto calibration function

• Auto clean function

 

• EEPROM parameters storage

• Automatic overload protection and reset

• Extractable terminal blocks

• 96X96 (1/4” DIN) housing

 

This model includes the auto calibration and auto cleaning functions of the

sensor, done by external devices activated by the instruments.

For this, customers can make reliable and affordable ISE analyzers,

through the use of ISE electrodes, which in continues applications, require

frequent calibration and cleaning operations.

 

 

Specifications

 

Operating Mode

Automatic/ Manual

 

ISE electrodes input

* Type of Ion: X- -, X-, X+, X++

Measuring field: 5 decades from 0.01 to 1000

 

* Scale

10.00 – 1000 with auto ranging

Software filter 90%RT: 0.4/20.0 s for small/large variations

 

Calibration

Up to 5 points on the entire scale

Zero adjustment: ±100.0 mV

Range mV: ±1100.0 mV

 

Temperature

Input: RTD Pt100 3 wires

Measuring field: -10/100°C

Resolution: ±0.1°C

Zero correction: ±2°C

Manual temperature: -10/100°C

 

 

 

 

 

Thermo compensation

Compensation field: -10/110°C

Ref. temperature: 20°C

 

* Auto calibration function

Disabled – Manual – Automatic + manual

* Repetition time: 1/999 hours

* Calibration time: 0.1/19.0 minutes

* Restoring time: 0.1/19.0 minutes

* Standard solutions: 0.01/1000 PPM

 

* Auto cleaning function

Disabled – Manual – Automatic + manual

* Repetition time: 1/999 hours

* Cleaning time: 0.5/60.0 seconds

* Restoring time: 0.1/19.0 minutes